One team carries the fire and life safety scope: code consulting, design, third-party review, Civil Defence approval, Salamah reports and site support.


Code consulting

Interpretation of SBC and NFPA requirements from concept stage, so the design starts on the right path and the architect knows the fire limits before layouts are fixed.

  • Occupancy classification and construction type
  • Allowable heights and areas
  • Fire strategy options and their cost impact
  • Code matrix the whole design team can work from

Fire & life safety design

Fire strategy reports and complete FLS drawing packages for egress, compartmentation and every fire protection system, with the calculations behind them.

  • Fire strategy report
  • FLS drawings for egress, compartmentation and fire protection systems
  • Hydraulic, battery and voltage drop calculations
  • Specifications and schedules

Design review & stamping

Independent review of other consultants' FLS and fire MEP designs, a graded comment register, and stamping once the design complies.

  • Review against SBC 801, SBC 201 and NFPA
  • Comment register graded High, Medium or Low
  • Follow-up review of the revised drawings
  • Stamped drawings once the design complies

Authority approvals

Civil Defence (Salamah) and Balady submissions, comment responses and close-out, handled by the same engineers who prepared the design.

  • Submission package prepared and uploaded on Salamah
  • Balady coordination where the licence needs it
  • Comment log and written responses
  • Close-out through to approval

Salamah technical reports

Fire compliance technical reports on the Salamah platform for Balady licence renewals, from the site visit to the issued report.

How a Salamah technical report works


Site support

Shop drawing review, inspection, testing and commissioning support, and the as-built review at handover.

  • Shop drawing and material submittal review
  • Site inspections with a photo record
  • Witnessing tests and commissioning
  • As-built review at handover

Systems we design

What each package contains and the standards it is designed to.

Fire alarm & detection

Addressable fire alarm and detection design, from device layout to loop design, voice evacuation and the cause-and-effect matrix. Every package is designed to NFPA 72 and SBC 801 and includes battery and cable calculations.

  • Detector, call point and sounder layouts
  • Loop wiring and riser diagrams
  • Voice evacuation and paging zones
  • Cause-and-effect matrix
  • Battery and voltage drop calculations
  • Interfaces with sprinklers, HVAC, lifts and access control
NFPA 72SBC 801SBC 201

Sprinklers & water systems

Wet, dry and pre-action sprinkler systems, standpipes, fire hose cabinets, hydrant networks, fire pumps and water storage, all supported by full hydraulic calculations.

  • Sprinkler layouts and hazard classification
  • Hydraulic calculations and pipe sizing
  • Fire pump, jockey pump and tank sizing
  • Standpipes, hose cabinets and hydrants
  • Fire department connections
NFPA 13NFPA 14NFPA 20NFPA 22NFPA 24

Clean agent & special hazards

Clean agent, foam and kitchen hood suppression for rooms where water would do more harm than good, or where the hazard needs a dedicated system.

  • Clean agent systems for server and IT rooms
  • Foam systems for fuel and special hazards
  • Kitchen hood suppression
  • Special hazard risk review
NFPA 2001NFPA 11NFPA 17ANFPA 96

Means of egress & emergency lighting

Occupant load, exit capacity, travel distance, common path and dead-end checks for every floor. Exit signage, emergency lighting and door hardware schedules are prepared alongside the layouts.

  • Occupancy classification and occupant load per floor
  • Exit width, number of exits and remoteness
  • Travel distance, common path and dead-end checks
  • Exit stair, exit passageway and refuge area layouts
  • Exit signage and emergency lighting layouts
  • Door hardware and locking schedules
SBC 201SBC 801NFPA 101NFPA 110

Smoke control & pressurisation

Car park ventilation and smoke clearance, atrium smoke control, stair and lift shaft pressurisation, and smoke exhaust for malls and assembly spaces, with CFD and tenability analysis where the project needs it.

  • Smoke control strategy and zoning
  • Car park jet fan and extract layouts
  • Atrium and mall smoke exhaust sizing
  • Stair and lift shaft pressurisation
  • Smoke and fire damper schedules
  • CFD and tenability studies when required
NFPA 92NFPA 90ASBC 501SBC 801

Passive fire protection

Fire-rated construction that keeps a fire in the room where it starts, so the active systems and the escape routes can do their job.

  • Fire-rated walls and floors
  • Fire doors and opening protection
  • Compartmentation and firestopping details
  • Door schedules
SBC 201NFPA 80

Sectors we serve

A fire strategy depends on who uses the building and how. These are the building types we know well.

Commercial & mixed-use

Malls, offices, showrooms and mixed-use podiums

Healthcare & laboratories

Hospitals, clinics and laboratory fit-outs

Hospitality & leisure

Hotels, serviced apartments and sports venues

Industrial & warehousing

Factories, logistics centres and automotive sites

Residential compounds & towers

Villa compounds, townhouses and high-rise blocks

Education & public buildings

Schools, mosques, daycare and civic buildings

Tell us about your building

Share the drawings or a short description and we will propose the right scope.